Knick Portamess® 911 Oxy with Knick SE 302 oxygen sensor
Portamess® 911 Oxy
The basic unit for the mobile oxygen measurement. Clearly. Uncomplicated.
The facts:
* Measured with flow free oxygen sensors; stirrer is not required
* Automatic calibration on air (in the device's calibration vessel) with one button operation
* Automatic correction for temperature and pressure influences
* Permanent polarization of the sensor for measurement of immediate
* Sensors maintenance
* Measurements in the laboratory / field sensor SE 302 - immersion measurements with SE 303
* Comparison or control measurements of process sensors with adapter cable
* Possibility to enter the salt content to correct the solubility
* Zero point calibration of sensors articulated not necessary, but possible for sensors with offset
* Calibration timer
* Simultaneous display of temperature and oxygen Size
* Display of oxygen saturation index, or oxygen concentration
* Power Up with display control
* Low battery warning
* 1000 hours with only 3 AA batteries (AA)
* Shutdown (polarization voltage of the sensor is not turned off)
* 200 values may be stored with date and time
* Data Logger
Technical data:
Measuring current ranges 0 ... NA 600
Oxygen saturation 0.0 ... 600.0% (0 ° C to 55 ° C) Operating error: 0.5% of reading +0.2% saturation
Oxygen concentration of 0.00 ... 60.00 mg / l (0 ° C to 55 ° C) Operating error: 0.5% of reading +0.05 mg / l
Pressure range 700 ... 1080 hPa
Salt correction configurable to 0.00 ... 45.00 g / kg, solubility EN 25 814
Sensor adjustment [cal] Auto air to water vapor in the quiver, zero point calibration possible
Calibration zero (zero) ± 2 nA, slope (Slope) 25 ... 130 nA
Calibration timer 0 ... 14 days, default 6 days
Pressure correction automatically via built-in pressure sensor
Automatic temperature compensation with integrated NTC 22 kOhm in Sensor
Measuring range 0.0 ... +55.0 ° C / 32 ... +131 ° F
Resolution 0.1 ° C / 1 ° F
Operating error <0.5 K
Device self-test automatically switched
Data preservation parameters and calibration data> 10 years (EEPROM)
EMC Directive 89/336 / EEC
EMC standard DIN EN 61326 / VDE 0843 Part 20: 2002-3
Ambient operating / ambient temperature. -10 ... +55 º C; transport and storage temperature. -10 ... +70 º C
Display LCD 67 x 35 mm, height 15 mm; Display: mg / l,%, º C
Power 3 AA batteries (AA), operating time is about 1000 h; autom. Off after an hour or 12 hour selectable
Housing material: PA, protection: IP 66, with integrated sensor Quiver
Dimensions / Weight 133 x 160 x 30 mm (W x H x D) / 560 g with batteries
SE 302 oxygen sensor
Flow free work and provide highly accurate values, the constant polarization
The sensors also ensures permanent operational readiness.
Technical data:
Sensitivity of 40 ... 80 nA at 25 º C in air
Polarization voltage -670 + / -50 mV
Typical stabilization time 15 min., Max. 1 h
Temperature sensor NTC 22 kOhm
Temperature range 0 ... 60 º C
Shaft diameter 12 mm
Wetted materials, PPS, PTFE, silicone, Viton
Flow dependence <5% at 25 º C
Leakage current <0.5% of electricity in air
Cable SMEK fixed cable connector, length 1,5 m
Condition: New